Single-shot and single-spot measurement of laser ablation threshold for carbon nanotubes
physics.optics
/ Authors
/ Abstract
A simple and convenient procedure for single-shot, single-spot ablation threshold measurement has been developed. It is based on the employment of cylindrical lens to obtain elliptical Gaussian laser spot. The ablated spot chords which are parallel to the minor axis were measured across the spot major axis which is proportional to the fluence cross-section thus providing wide range dependence of damaged spot size versus fluence in one spot measurement. For both conventional and new-developed procedures the ablation threshold for typical Nd:YAG laser parameters (1064 nm, 10 ns) has been measured as 50 mJ/cm2 which is one order of magnitude lower than that for a bulk graphite.